NHN Water Technologies Pvt. Ltd., provides ‘Total Solution’ in water
engineering. We provide ‘Customized Complete Plant on Turnkey Basis’ as per
your specific requirement along with our technical know-how, peripherals and
support services. We outsource products from their respective market leaders
from France, Germany, Italy, Japan and India.
Chemical
Dosing
For Dosing of chlorine, pH adjustment, Antiscaling and Remineralisation
Chemicals
Standard Features
-
Upto three tank mineral injection system to hold three seperate mineral
batches.
-
PLC- operated control panel complete with flow meter, TDS monitor.
-
Control panel monitors mineral or other chemical composition of outlet water.
-
Low level control for tanks.
-
No flow- No dosing mechanism.
-
Electronic chemical injection pump for precision mineral dosing or chemical
dosing.
-
On-line static mixer.
|
Optional Features
-
Skid Mounted Systems for compact design.
-
Customised design for separate dosing minerals up to three tanks.
-
Tank capacity 30 to 50 gallons with lids.
-
Stirrers for chemical mixing in tank.
-
Safety Alarm.
-
Powder coated with chemical resistant paint.
|
Electronic metering pumps
SERIES NHN – A
-
Manual function controls for Stroke Rate and Stroke Length.
-
High reliable timing circuit.
-
EMI resistant.
-
Thermally protected solenoid with auto reset.
-
Bleed valve assembly.
|
|
SERIES NHN – C
-
Our low cost alternative.
-
Manual function control for Stroke length.
-
Highly reliable timing circuit.
-
Thermally protected solenoid with auto reset.
-
Bleed valve assembly.
|
|
Series
| NHN / 1.1 / A / 6-30 |
02
|
03
|
04
|
64
|
|
Capacity,
nominal
|
GPD
|
6
|
12
|
22
|
30
|
|
GPH
|
0.25
|
0.50
|
0.91
|
1.25
|
|
LPD
|
22
|
44
|
83
|
113.50
|
Pressure,
max.
PSIG / Bar |
P
/ N
|
P
/ N
|
P
/ N
|
P
/ N
|
|
150
/ 10
|
02
|
03
|
-
|
-
|
|
100
/ 7
|
-
|
-
|
04
|
64
|
|
Series
| NHN
/ 1.1 / C / 6-30 |
02
|
03
|
04
|
64
|
|
Capacity,
nominal
|
GPD
|
6
|
12
|
22
|
30
|
|
GPH
|
0.25
|
0.50
|
0.91
|
1.25
|
|
LPD
|
22
|
44
|
83
|
113.50
|
Pressure,
max.
PSIG / Bar |
P
/ N
|
P
/ N
|
P
/ N
|
P
/ N
|
|
80
/ 5.6
|
02
|
03
|
04
|
54
|
|
| SPECIFICATIONS |
NHN /
1.1 / A / 6-30 |
NHN
/ 1.1 / C / 6-30 |
Pressure, max: PSI
BAR
@ CPD / CPH / LPD |
150 / 10
12 / 0.50 / 44 |
80 / 56
30 / 1.25 / 113 |
Capacity (normal),
max: GPD / GPH / LPD
@PSI / BAR |
30 / 1.25 / 113
100 / 7 |
30 / 1.25 / 113
80 / 5.6 |
| Reproducibility, at max
Capacity: % (1) |
3 |
3
|
| Viscosity Max: CPS |
1000 |
1000 |
| Suction Lift @ CPS, max: ft / M |
5 / 15 ( once primed ) |
5 / 1.5 ( once primed ) |
| Stroke Frequency, max SPM
(Manual) |
125 |
125 |
| Stroke Frequency turn - Down
Ratio |
10:1 |
N/A |
| Stroke Length Control (Manual)
|
On. Line Adjustable |
On. Line Adjustable |
| Stroke Length Turn - Down Ratio |
10:1 |
5:1 |
| Power Input |
115VAC / 50-60Hz / 1 ph
230VAC / 50-60Hz / 1 ph
|
115VAC / 50-60Hz / 1 ph
230VAC / 50-60Hz / 1 ph
|
| Average Current Draw @ 115 VAC:
Amps |
0.6 |
0.6 |
| Peak Input Power, Watts |
130 |
130 |
| Average Input Power @ max SPM
Watts |
50 |
50 |
| Circuit Board Protection |
Fuse, 1.5 Amp (Board-Mount) |
Fuse, 1.5 Amp (Board-Mount) |
|
Connections - Tubing
Piping
|
1/4" ID x 3/8" OD
3/8" id x 1/4" OD
1/4" FNPT
|
1/4" ID x 3/8" OD
3/8" id x 1/4" OD
1/4" FNPT
|
| Injection anti - Siphon |
Standard |
Standard |
| Foot Valve / Strainer, w /
Tubing |
Standard |
Standard |
| Bleed Valve Assembly, w / Tubing |
Standard |
Standard |
Multimedia & Carbon Filtration
Multimedia Filtration
NHN Multi-media filter are ideal for removal of fine suspended
particles present in the source water. The deep-bed systems use 4 layers of
media supported by gravel-bed at the bottom. Suspended particles upto 30 micron
size are efficiently removed at the system flow rate of 10 gpm/ft. The systems
require backwashing to remove the accumulated contamination of suspended
particles and rinsed by downflow clean filtered water before use.
Multi-media filters available with Automatic and or manual
operational features.
NHN / 1.2 / MMF / FRP / 5 - 110 SERIES
|
MODEL
NO.
|
DIAMETER
|
HEIGHT
|
MEDIA
CU.FT.
|
PAPER
SIZE
|
FLOW
RATE
(G.P.M)
|
BW
(G.P.M)
|
SHIPPING
WEIGHT
|
| NHN / 1.2 / MMF / FRP/ 5 |
10
|
54
|
1.6
|
1"
|
5
|
7
|
225 lbs.
|
| NHN / 1.2 / MMF / FRP/ 8 |
12
|
52
|
2.5
|
1"
|
8
|
12
|
225 lbs.
|
| NHN / 1.2 / MMF / FRP/ 10 |
13
|
54
|
2.95
|
1"
|
10
|
12
|
410 lbs.
|
| NHN / 1.2 / MMF / FRP/ 12 |
14
|
65
|
3.7
|
1"
|
12
|
15
|
510 lbs.
|
| NHN / 1.2 / MMF / FRP/ 15 |
16
|
65
|
5.2
|
1.5"
|
15
|
20
|
715 lbs
|
| NHN / 1.2 / MMF / FRP/ 26 |
22
|
60
|
8.8
|
1.5"
|
26
|
40
|
1160 lbs.
|
| NHN / 1.2 / MMF / FRP/ 30 |
24
|
71
|
11.5
|
2"
|
30
|
45
|
1520 lbs.
|
| NHN / 1.2 / MMF / FRP/ 50 |
30
|
72
|
35
|
3"
|
50
|
70
|
2460 lbs
|
| NHN / 1.2 / MMF / FRP/ 70 |
36
|
72
|
26.5
|
2"
|
70
|
90
|
3455 lbs
|
| NHN / 1.2 / MMF / FRP/ 110 |
42
|
72
|
18.5
|
2"
|
110
|
100
|
4900 lbs.
|
Activated Carbon Filtration
NHN Activated carbon filters are very efficient to remove
chlorine, colour, odour,organic elements & pesticide residues by adsorption
process. The highly porouscoconut-shell Granular Activated carbon media
provides larger surface area for efficient removal of contaminants at higher
flow rates
Periodic backwashing advised to clean the Granular Activated
Carbon for efficient functioning and longer life of media. Activated Carbon
Filters available with Automatic or manual operational features.
NHN / 1.2 / ACF / FRP / 3 - 100 SERIES
|
MODEL
NO.
|
DIAMETER
|
HEIGHT
|
MEDIA
CU. FT
|
PIPE
SIZE
|
FLOW
RATE
(G.P.M)
|
|
SHIPPING
WEIGHT
|
|
NHN / 1.2 / ACF
/ FRP / 3
|
10
|
40
|
1.20
|
3/4"
|
3
|
5
|
65 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 5
|
10
|
54
|
1.60
|
3/4"
|
5
|
5
|
80 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 8
|
12
|
52
|
2.2
|
1"
|
8
|
7
|
125 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 10
|
13
|
54
|
2.8
|
1"
|
10
|
8
|
150 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 12
|
14
|
65
|
3.4
|
1"
|
12
|
10
|
180 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 12
|
14
|
65
|
3.4
|
1.5"
|
12
|
10
|
190 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 15
|
16
|
65
|
4.5
|
1"
|
15
|
12
|
240 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 15
|
16
|
65
|
4.5
|
1.5"
|
15
|
12
|
245 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 26
|
22
|
60
|
7.0
|
1.5"
|
26
|
25
|
435 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 30
|
22
|
60
|
8.0
|
1.5"
|
30
|
25
|
465 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 40
|
24
|
71
|
10.5
|
1.5"
|
40
|
30
|
575 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 40
|
24
|
71
|
10.5
|
2"
|
40
|
30
|
590 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 50
|
30
|
72
|
15.0
|
2"
|
50
|
50
|
855 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 70
|
36
|
72
|
24.0
|
2"
|
70
|
70
|
1780 lbs.
|
|
NHN / 1.2 / ACF
/ FRP / 100
|
42
|
72
|
30
|
3"
|
100
|
90
|
2750 lbs.
|
Softener - Single Tank Water Conditioners
 |
NHN Softener are equipped with Cation Exchange Resin media
placed on gravel bed to reduce hardness of water. Compounds of Calcium and
Magnesium impart hardness to water are responsible for scaling of pipes and
earlier fouling of RO membranes. The cation exchange resin replaces calcium,
magnesium and other cations present in water with sodium ions.
Systems designed to suit process and regeneration cycle requirements specified
by the customer. Easy operations featured with automatic and or manual
functions are available.
|
NHN / 1.3 / SFT / FRP / 90 - 1200K SERIES
|
MODEL
NUMBER
|
CUBIC
FEET
|
FLOW
RATES
(G.P.M.)
|
MAXIMUM
GRAINS
|
SIZE
OF TANK
(INCHES)
|
APPROX.
SHIPPING
WEIGHT
(POUNDS)
|
|
CONT.
|
PEAK
|
MINERAL
|
BRINE
|
|
NHN/1.3/SFT/FRP/-90
|
3
|
39
|
54
|
90,000
|
14 x 65
|
22 x 36
|
330
|
|
NHN/1.3/SFT/FRP/-170
|
4
|
47
|
64
|
120,000
|
16 x 65
|
24 x 48
|
385
|
|
NHN/1.3/SFT/FRP/-180
|
6
|
60
|
77
|
180,000
|
22 x 60
|
24 x 48
|
535
|
|
NHN/1.3/SFT/FRP/-240
|
8
|
68
|
91
|
240,000
|
24 x 60
|
24 x 48
|
640
|
|
NHN/1.3/SFT/FRP/-300
|
10
|
68
|
91
|
300,000
|
24 x 71
|
24 x 48
|
640
|
|
NHN/1.3/SFT/FRP/-450
|
15
|
85
|
100
|
450,000
|
30 x 72
|
30 x 48
|
1230
|
|
NHN/1.3/SFT/FRP/-600
|
20
|
85
|
100
|
600,000
|
36 x 72
|
30 x 48
|
1650
|
|
NHN/1.3/SFT/FRP/-750
|
25
|
90
|
105
|
750,000
|
36 x 72
|
30 x 60
|
1900
|
|
NHN/1.3/SFT/FRP/-450
|
15
|
98
|
122
|
450,000
|
30 x 72
|
36 x 48
|
1585
|
|
NHN/1.3/SFT/FRP/-600
|
20
|
141
|
176
|
600,000
|
36 x 72
|
42 x 48
|
2109
|
|
NHN/1.3/SFT/FRP/-750
|
25
|
176
|
220
|
750,000
|
36 x 72
|
48 x 48
|
2368
|
|
NHN/1.3/SFT/FRP/-900
|
30
|
192
|
240
|
900,000
|
42
x 72
|
52
x 60
|
3313
|
|
NHN/1.3/SFT/FRP/-1200
|
40
|
213
|
280
|
1,200,000
|
48 x 72
|
52 x 60
|
4110
|
Softener - Twin tank water conditioners for continuous
use
-
The systems have applications for continuous process operations. Alternate use
of the tank is possible with Automatic and or manual operations. System is
always ready without any stoppage for regeneration of cation exchange resin.
Optional features
-
Flow-metering device for Automatic
-
Regeneration of tanks alternatively
-
Hardness test kit
-
Pressure indicator
NHN / 1.3T / SFT / FRP / 90 - 1200K SERIES
|
MODEL
NUMBER
|
CUBIC
FEET
|
FLOW
RATE
(G.P.M.)
|
MAXIMUM
GRAINS
|
SIZE
OF TANK
(INCHES)
|
APPROX.
SHIPPING
WEIGHT
(POUNDS)
|
|
CONT.
|
PEAK
|
MINERAL
|
QTY
|
BRINR
|
QTY
|
|
NHN/1.3T/SFT/FRP/90
TWIN
|
6
|
39
|
54
|
50,000
|
14
x 65
|
2
|
22
x 36
|
2
|
660
|
|
NHN/1.3T/SFT/FRP/120
TWIN
|
8
|
47
|
64
|
120,000
|
16
x 65
|
2
|
24
x 40
|
2
|
770
|
|
NHN/1.3T/SFT/FRP/180
TWIN
|
12
|
60
|
77
|
180,000
|
22
x 60
|
2
|
24
x 48
|
2
|
1070
|
|
NHN/1.3T/SFT/FRP/240
TWIN
|
16
|
68
|
91
|
240,000
|
24
x 60
|
2
|
24
x 48
|
2
|
1280
|
|
NHN/1.3T/SFT/FRP/300
TWIN
|
20
|
68
|
91
|
300,000
|
24
x 71
|
2
|
24
x 48
|
2
|
1680
|
|
NHN/1.3T/SFT/FRP/450
TWIN
|
30
|
85
|
100
|
450,000
|
30
x 72
|
2
|
30
x 48
|
2
|
2460
|
|
NHN/1.3T/SFT/FRP/600
TWIN
|
40
|
85
|
100
|
600,000
|
36
x 72
|
2
|
30
x 48
|
2
|
3300
|
|
NHN/1.3T/SFT/FRP/750
TWIN
|
50
|
90
|
105
|
750,000
|
38
x 72
|
2
|
30
x 60
|
2
|
3800
|
|
NHN/1.3T/SFT/FRP/450
TWIN
|
30
|
98
|
122
|
450,000
|
30
x 72
|
2
|
36
x 48
|
2
|
3170
|
|
NHN/1.3T/SFT/FRP/600
TWIN
|
40
|
141
|
176
|
600,000
|
36
x 72
|
2
|
42
x 48
|
2
|
4218
|
|
NHN/1.3T/SFT/FRP/750
TWIN
|
50
|
176
|
220
|
750,000
|
36
x 72
|
2
|
48
x 48
|
2
|
4738
|
|
NHN/1.3T/SFT/FRP/900
TWIN
|
60
|
192
|
240
|
900,000
|
42
x 72
|
2
|
52
x 60
|
2
|
6626
|
|
NHN/1.3T/SFT/FRP/1200
TWIN
|
80
|
213
|
280
|
1,200,000
|
48
x 72
|
2
|
52 x 60
|
2
|
8220
|
Micron / Absolute Filtration
Up- Flow Stainless Steel Industrial Filter Housings
Cartridge filters (304 stainless steel, CPVC standpipes, CPVC
cartridge holders & threaded caps.)
Cartridge cluster filters (for one stretch removal of entire
set)
| NHN/1.4/MF/SS/30
- 800 SERIES |
NHN/1.4/MF/30
|
NHN/1.4/MF/60
|
NHN/1.4/MF/75
|
NHN/1.4/MF/90
|
NHN/1.4/MF/105
|
NHN/1.4/MF/300
|
NHN/1.4/MF/400
|
NHN/1.4/MF/600
|
NHN/1.4/MF/800
|
| Flow rate (GPM) |
Up to 30
|
Up to 60
|
Up to 75
|
Up to 90
|
Up to 105
|
Up to 300
|
Up to 400
|
Up to 600
|
Up to 800
|
| Number of std Catridges |
7
|
14
|
16
|
21
|
24
|
75
|
100
|
150
|
200
|
| Alternative cartridge
|
Single only
|
7 doubles
|
8 doubles
|
7 triples
|
8 triples
|
25 triples
|
50 doubles
|
50 triples
|
100 doubles
|
| Pipe size (Male NPT)
|
1 1/2"
|
1 1/2"
|
2"
|
1 1/2"
|
2"
|
3"
|
3"
|
4"flanged
|
4"flanged
|
| Filter height
|
19.5"
|
28"
|
28"
|
37"
|
37"
|
42"
|
52"
|
48"
|
58"
|
| Floor space required
|
13" x 13"
|
13" x 13"
|
13" x 13"
|
13" x 13"
|
13" x 13"
|
20" x 20"
|
20" x 20"
|
28" x 28"
|
28" x 28"
|
| Service height clearance |
35"
|
48"
|
48"
|
68"
|
68"
|
70"
|
87"
|
76"
|
93"
|
| Shipping weight (approx) |
29lbs.
|
39lbs.
|
39lbs.
|
50lbs.
|
50lbs.
|
129lbs.
|
188lbs.
|
274lbs.
|
321lbs.
|
| Pressure rating
|
150 psi
|
150psi
|
150psi
|
150psi
|
150psi
|
150psi
|
150psi
|
150psi
|
150psi
|
Fluid enters the filter under pressure and flows through the
filter media, holes in the center tubes and perforations in the rods that hold
the cartridges in place. As the fluid continues its path, it flows upward past
the top seat where it splits over into the standpipe as it hits the filter's
domed lid. Notice the top of the standpipe is at high point of the filter.
Also, note the filter catridges are sealed at the bottom and held in place with
threaded pipe caps. This unique design offers the following significant
advantages:
-
No Air Entrapment During Operation
Air entrapment during operation is eliminated because the outlet is located at
the high point of the filter above inlet.
-
No Fluid By-pass During Servicing
Fluids cannot by-pass filters during servicing because the
filter's outlet (top of standpipe) is located above the filter's inlet. A
significant advantage in critical filtration applications.
-
Pressure Rated
Industrial Filters may be safely used in pressures up to 150
psi.
-
Fail-Safe Lids
Lids come standard with wing nuts so they may be easily opened
without tools. Multiple studs provide | |